Introduction
Burying wires in concrete is a common task when running electrical wiring in new construction or renovation projects. Properly embedding wires in concrete ensures the wiring is protected and hidden from view. However, careful planning and execution is required to avoid safety hazards and code violations. This comprehensive guide will walk through all the key steps and considerations when burying wires in concrete.
Safety Precautions
When working with electricity, it's critically important to take proper safety precautions. Here are some key guidelines:
-
Use GFCI protection - Ground-fault circuit interrupter (GFCI) outlets or breakers detect dangerous current leakage and shut off power to prevent electrocution accidents. GFCI protection should always be used when working with electrical wiring.
-
Wear rubber-soled shoes - This type of footwear provides insulation when working with electricity. Never work barefoot or in damp conditions.
-
Use insulated tools - Hand tools like screwdrivers and pliers should have insulated rubber handles. This prevents accidental shocks.
-
Turn off power - The power should always be switched off at the breaker panel when working on electrical wiring. Verify power is off by testing with a multimeter or voltage tester.
-
Beware of buried cables - Assume underground wires are live. Avoid digging in unknown areas until electrical lines are identified and marked.
Choosing Appropriate Wiring
The type of wiring used for burying in concrete must be rated for wet locations and meet electrical code requirements:
-
USE/RHH/RHW-2 wire - This is a common single conductor wiring for wet and underground installations. The thick PVC insulation stands up to moisture. Different gauge sizes are available based on electrical load requirements.
-
UF cable - Underground feeder (UF) cable contains insulated conductors bundled together in a PVC outer jacket. It is more convenient to install than individual wires.
-
Conduit - Plastic or metal conduit provides an extra layer of protection for running wires underground. The wires are pulled through the conduit after it is buried.
-
Direct burial cable - This specialized multiconductor cable contains an impervious moisture-blocking layer under the outer jacket. It can be buried directly without conduit.
The wiring should be clearly marked as approved for wet locations and direct burial. Choose the minimum size required for the electrical load to avoid de-rating issues when buried in concrete.
Digging the Trench
Burying wiring in concrete starts with digging a trench to lay the conductors:
-
Depth - For circuits under 120V, trenches in interior slabs should be at least 4 inches deep. For exterior slabs and higher voltages, the depth increases to 6 inches or more.
-
Width - The trench should be wide enough to allow at least 3 inches of concrete on all sides of the wiring. common widths are 3-6 inches.
-
Routing - Plan the trench route to avoid high-traffic areas on the slab. Keep wiring runs as short and straight as possible.
-
Over-digging - When digging with a shovel, over-dig the bottom by 2 inches. This allows a 2 inch layer of sand as a wiring bed.
-
Conduit - If installing wiring in conduit, dig deep enough to leave 3 inches of concrete beneath the conduit for support.
Avoid digging trenches too far in advance of wiring installation to prevent erosion issues or accidental cave-ins. Inspect the trench bottom for sharp rocks and protrusions before laying any wiring.
Installing the Wiring
The wiring should be properly positioned in the trench before pouring concrete:
-
Laying - Place the wiring in the center of the trench running straight without sharp bends. For multiple wires, bundle them together with tape at intervals.
-
Spacing - Keep at least 2 to 3 inches spacing between parallel wire runs. This prevents overheating issues.
-
Covering - In a conduit-free installation, cover direct burial wiring with 2 inches of sand or earth before concrete. This protects the insulation.
-
Anchoring - Anchor cables frequently with stakes or ties to prevent them from floating during concrete pour.
-
Junction boxes - Install buried junction boxes wherever wiring splices are required. Use boxes rated for wet locations.
-
Above-slab access - Leave at least 6 inches of extra wire above the top of the planned slab to make connections. Coil the excess neatly out of the way.
Avoid placing too many wires close together or kinking cables at tight corners. Plan wiring runs carefully before installation to prevent problems.
Pouring and Finishing the Concrete
With wiring installed properly in the trench, the process of pouring and finishing the concrete slab can begin:
-
Inspect wiring - Before any concrete work, double check that wiring is continuous, undamaged, and anchored securely.
-
Pour carefully - Prevent damage to cables by pouring concrete slowly and evenly over trenches. Use a vibrator cautiously around wires.
-
Avoid disturbing wires - After pouring, do not attempt to trowel or finish concrete directly over top of buried wiring.
-
Add reinforcement - For lengthy trench runs, consider adding steel rebar or welded wire fabric to prevent concrete cracking.
-
Watch slab depth - Ensure concrete meets the required coverage depth over wiring per code requirements.
-
Make wire connections - After concrete has cured, make electrical connections to buried wiring above the slab as planned.
Take care throughout the concrete installation process to keep wiring fully protected. Repair any cracks or damage that occur above buried wires before completing the electrical system.
Common Code Requirements
It is crucial to follow local electrical codes and standards when burying wiring in concrete. Some key requirements include:
-
Wet location rating - All wiring must carry a wet location or similar water-resistant rating.
-
Conduit use - Nonmetallic conduit may be required for some types of buried wiring in concrete.
-
Concrete coverage - Wiring typically requires at least 1.5 to 2 inches of concrete surrounding it.
-
Trench depth - Trenches in a slab must meet the minimum depth for the type of wiring and application.
-
GFCI protection - Buried wiring may need GFCI devices if near water sources or part of a damp location.
-
Inspection - In some areas, a rough electrical inspection is required before pouring concrete over buried wiring.
Consult your local building department for specific codes covering electrical systems encased in concrete. Planning your project carefully to meet the requirements avoids issues down the road.
Conclusion
Burying wires safely in concrete involves careful planning, proper materials selection, and code-compliant installation steps. But when done correctly, this wiring method provides a hidden infrastructure solution suitable for both indoor and outdoor applications. Following the guidelines in this article will lead to success on your next project involving electrical wiring encased in concrete.