Introduction
Proper grounding is essential for safety and preventing equipment damage. However, in some situations, using a ground rod is not possible or ideal. This article will discuss what grounding is, why it's important, and how to achieve proper grounding without a ground rod.
What is Grounding?
Grounding refers to connecting electrical equipment to the earth. This provides a safe path for electricity to flow to the ground in the event of a fault or overload condition.
Proper grounding is vital for:
-
Safety - It prevents electric shock by providing an alternative path for electricity that bypasses a person.
-
Equipment protection - It prevents damage to equipment by providing a path for excess currents.
-
Noise reduction - It minimizes electrical noise in signals and shields sensitive devices.
Why Ground Rods Are Typically Used
Ground rods are commonly used to create earth grounds. A ground rod (or grounding rod) is a metal rod or pipe driven into the earth. They provide a simple, low resistance path to ground.
Ground rods have several advantages:
-
They are inexpensive and easy to install.
-
When properly installed, they provide a reliable, permanent ground.
-
They have low resistance (typically 10 ohms or less).
-
They are maintenance free. Once installed, no upkeep is required.
For these reasons, building codes often require using ground rods for grounding electrical systems. However, ground rods are not always ideal or possible to install.
When Not to Use Ground Rods
There are some situations where using ground rods is not recommended or feasible:
-
Rocky soil - Driving rods into rocky ground can be very difficult or impossible. The high resistance of rocks reduces effectiveness.
-
Frequent lightning - In areas with frequent lightning strikes, ground rods can become damaged over time. The grounding path degrades.
-
Temporary installations - Ground rods are meant for permanent installations. They are less convenient for temporary sites.
-
Moisture issues - Wet soil or flooding can cause ground rod resistance to fluctuate seasonally.
-
Ground contamination - Rods can become surrounded by contaminated soil or hazardous materials underground.
-
Concrete foundations - Rods cannot be installed in concrete building foundations lacking earth contact.
In these cases, alternative grounding methods may be better options.
Grounding Without Ground Rods
When ground rods are not ideal, proper grounding can be achieved through these alternative methods:
Concrete-Encased Electrode
For concrete foundations and buildings, using a concrete-encased electrode is an option. This involves embedding bare copper conductor within the concrete foundation or footing.
Local Metal Underground Systems
Existing buried metal systems can be used if they qualify under electrical code:
-
Metal water pipe - Cold water pipes that run underground can provide a grounding path.
-
Metal frame of building - In reinforced concrete buildings, connecting to the rebar network is permitted.
-
Metal well casing - Metal casings of water wells make suitable grounding electrodes.
Made Electrodes
Made electrodes are specially produced grounding electrodes:
-
Ground rings - Bare copper conductor buried in a ring configuration below grade.
-
Ground plates - Copper or non-corroding plates buried below the surface.
-
Conductive concrete - Concrete with conductive materials like steel or carbon added.
Supplemental Electrode Required
In some installations, a supplemental electrode may be required in addition to one of the above electrodes. This helps achieve an adequately low ground resistance. Common options for supplemental electrodes include:
- Ground rods
- Ground rings
- Ground plates
The key is using an electrode or combination of electrodes that will provide a ground resistance low enough to satisfy electrical safety codes. Testing the ground resistance with a meter ensures proper grounding.
Following Proper Installation Procedures
When installing alternative grounding electrodes:
-
Follow all electrical code requirements for size of conductors, depth of burial, and spacing of electrodes.
-
Ensure all connections are tight and corrosion-resistant. Exothermic welds or irreversible compression connectors are recommended.
-
Label all ground wiring and electrodes appropriately for safety.
-
Measure the ground resistance and verify it meets requirements.
-
Be sure to bond all grounding electrodes together with the main grounding electrode system.
Conclusion
While ground rods are often used, there are many situations where alternative grounding methods are better options. Following proper procedures using concrete-encased electrodes, existing metal structures, made electrodes, and supplemental electrodes allows safe, code-compliant grounding without ground rods. The key is achieving adequately low ground resistance. With careful planning and installation, proper grounding can be accomplished without utilizing ground rods.