Grounding electrical systems properly is crucial for safety and preventing equipment damage in commercial buildings. However, tracking down obscure grounding problems can be challenging even for experienced maintenance personnel. This article provides an in-depth guide on how to systematically troubleshoot those tricky electrical grounding issues.
Understanding Electrical Grounding Fundamentals
Grounding provides a low resistance path to conduct fault currents safely to the earth. It also establishes a reference point for voltages in electrical systems. Key grounding principles in commercial buildings include:
- Equipment grounding - Connects noncurrent-carrying metal parts to ground to prevent shock if electrical insulation fails. Uses green or bare copper wire.
- System grounding - Connects current-carrying system neutral to ground at service entrance. Ensures predictable voltage levels.
- Lightning protection grounding - Diverts lightning strikes safely to earth. Uses thick bonding conductors.
- Static grounding - Drains static charges from equipment. Prevents sparks igniting flammable vapors.
Proper grounding is vital for safety and preventing damage to sensitive electronics. Fault currents can easily melt conductors if grounding is inadequate.
Diagnosing Obscure Grounding Problems
Obscure grounding issues often produce intermittent, inconsistent, or confusing symptoms. Common examples include:
- Random power glitches despite proper wiring
- Tingles from touching equipment enclosures
- Unexplained corrosion on metal components
- Flickering lights with all connections tight
- Electronics malfunctioning without apparent cause
Tracking down elusive grounding problems requires methodical troubleshooting. Follow these best practices:
Inspect All Bonds and Connections
- Check ground wires for corrosion and loose connections
- Verify all ground bonding jumpers are secure
- Inspect safety ground bolts holding equipment enclosures
- Measure contact resistances with a milliohm meter
Even small amounts of corrosion or looseness on ground points can cause issues. Clean and re-terminate suspect connections.
Check Ground Rod Resistance
- Use earth ground resistance tester to measure each ground rod
- Resistance should be under 25 ohms
- Drive additional rods if needed to reduce resistance
High ground rod resistance forces ground faults through sensitive equipment instead of earth.
Isolate Ground Loops
- Ground loops allow currents to circulate between grounds
- Use an isolation transformer or ground loop isolator to break loops
- Measure voltage drops across suspect ground points
Circulating currents from ground loops can induce noise voltages in circuits.
Confirm Neutral-to-Ground Bonds
- Check main service neutral-to-ground bond with an ohmmeter
- Verify separately derived systems have proper neutral bonds
- Only one bond should exist to avoid currents on ground wires
Missing or incorrect neutral-to-ground bonds can overload ground points.
Consider Stray Currents
- Measure currents on ground wires with clamp meter
- Inspect nearby rails, pipes, or structures for unusual voltages
- Check ground grid resistance to rule out earth currents
Stray currents from external sources like substations can cause ground problems.
When to Call in a Professional
If you've methodically checked all grounding with no resolution, consider hiring an electrical engineering firm for advanced diagnostics:
-
Engineers can perform earth ground grid resistance mapping to check for problem areas.
-
Firms may use oscilloscopes, network analyzers, or loop impedance testers to diagnose issues.
-
They can inspect the grounding design and recommend improvements.
For complex buildings, engineers can model ground grids and bonding to meet safety codes.
Proper grounding is too important to neglect in commercial facilities. Following systematic troubleshooting practices resolve obscure electrical grounding problems and prevent damage. For challenging issues, electrical engineering professionals can provide advanced diagnostic services. Paying attention to grounding helps ensure safe and reliable operation.