How to Troubleshoot a Malfunctioning Low Voltage Lighting System
Low voltage lighting systems provide accent and task lighting around homes and businesses. However, like any electrical system, low voltage lighting can develop issues. Troubleshooting a malfunctioning low voltage lighting system is usually straightforward with some basic knowledge. Here is an in-depth guide on how to troubleshoot a malfunctioning low voltage lighting system.
Checking the Power Source
The first step in troubleshooting a low voltage lighting system is to check the power source. Here are the key things to check regarding the power source:
Check the Transformer
-
Make sure the transformer is plugged in and getting power. Check that the outlet is working properly.
-
Verify the transformer is the correct wattage for the lighting system. Transformers are rated for a certain wattage load across all fixtures. An underpowered transformer can cause dim lights or no power.
-
Inspect the transformer for any signs of damage like cracks or burnt smells. A damaged transformer will need to be replaced.
Check Connections
-
Trace the low voltage wire connections back to the transformer. Make sure all connections are tight and secure.
-
Loose wire connections are a common cause of power issues. Tighten any loose wires with wire nuts or crimp connectors.
-
Check for any sliced or damaged wires that may be interrupting power flow. Damaged low voltage wiring will need to be spliced and repaired.
Reset GFCI Outlets
-
If the transformer is plugged into a GFCI outlet, try resetting it. Tripped GFCI outlets will cut power and need to be reset.
-
Test the outlet with a lamp to make sure it is providing power after resetting.
Inspecting the Fixtures
After verifying the transformer and connections, inspect the individual low voltage lighting fixtures:
Check Bulbs and Fittings
-
Remove bulbs and inspect sockets for issues. Corroded or damaged sockets can cause connection problems.
-
Test bulbs in a known good fixture to see if they are burnt out. Burnt out bulbs are a common issue.
-
Verify bulbs are the correct type and wattage for the fixture. Using incorrect bulbs can lead to problems.
Disassemble and Clean Fixtures
-
Take fixtures apart and clean contacts with rubbing alcohol. Dirt, corrosion, and oxidation on contacts can interrupt connections.
-
While disassembled, check for cracked solder joints or damaged wires within fixtures. Repair any internal wiring issues found.
Check Lens Seals
-
Make sure fixture lenses have tight seals to prevent water getting in. Moisture intrusion leads to corrosion and damages fixtures.
-
Look for mineral deposits or fogging inside lenses, indicating a bad seal. Reseal or replace any compromised lenses.
Testing the Low Voltage Wires
If the fixtures check out, the issue may be in the low voltage wiring:
Verify Voltage Level
-
Use a multimeter to check voltage at each fixture. Low or no voltage points to a wiring issue.
-
Ideal low voltage is 10-15V. Any readings significantly lower indicate a problem in the wiring.
Check for Breaks
-
Visually inspect along the full wire run looking for punctures, cuts, or damage. Broken wires are often visible.
-
Use a multimeter continuity setting to test each wire run for continuity. Any lack of continuity signals a break in the wiring.
Isolate Sections
-
Divide the lighting system into sections to isolate the problem area. Systematically test sections of fixtures to pinpoint wiring faults.
-
Check wire connections between sections for faults. Repair any damaged connections found between working and non-working sections.
Replace Faulty Wiring
-
For hardwired systems, damaged or degraded low voltage wiring will need to be replaced. Install fresh wiring as needed to resolve wiring faults.
-
For systems using removable wire, replace faulty wire runs with new low voltage cable.
When to Call an Electrician
While most low voltage lighting issues can be addressed DIY, there are times to call a professional electrician:
-
If the transformer has sustained significant damage or electrical shorts.
-
For wiring repairs that require accessing wall cavities or other construction areas.
-
If the exact cause of the issue cannot be found after thorough testing and troubleshooting.
-
For homes with older and outdated electrical systems. Faults in main electrical wiring can affect low voltage systems.
-
If you are not fully comfortable working with electrical wiring and fixtures. It is always safest to call an electrician if uncertain.
Troubleshooting low voltage lighting starts with methodically checking components and ruling out common issues. Pay close attention to connections and fixtures. For an older system, full rewiring may be needed. When in doubt, consult a professional electrician service for assistance.