Introduction
Underground wiring is an essential part of many electrical systems. For single phase circuits, epoxy resin insulated cables provide excellent protection and durability for underground applications. Proper installation practices are critical to ensure safety and longevity of underground wiring systems.
Epoxy Resin Insulated Cables
Epoxy resin insulated cables are commonly used for underground wiring as they offer:
-
Outstanding electrical insulation - The epoxy resin fully impregnates the paper insulation, enhancing dielectric strength.
-
Moisture resistance - The impervious epoxy resin prevents moisture ingress, avoiding insulation breakdown.
-
Chemical resistance - Epoxy resists oils, alkalis and acids, preventing insulation degradation.
-
Thermal endurance - The resin withstands high temperatures, enabling overload capacity.
-
Tough mechanical strength - Epoxy resin gives cables abrasion resistance and protection.
Common types of epoxy resin insulated cables include:
-
XLPE cables - Cross-linked polyethylene insulation with epoxy bonding.
-
EPR cables - Ethylene propylene rubber insulation with epoxy.
-
USE cables - Utilization service ethylene cables with epoxy impregnation.
Cable Selection
Selecting the right size and type of epoxy cable involves:
Conductors
-
Current rating - Match cable ampacity to expected load current.
-
Voltage rating - Ensure voltage insulation level exceeds system voltage.
-
Single core vs multi core - Single core for feeders, multi core for branching circuits.
-
Aluminum vs copper - Copper for feeders, aluminum for cost savings in branching.
Insulation
-
Temperature rating - 90°C minimum for general wiring, higher for special applications.
-
Withstand voltage - Cables must exceed the system voltage level.
-
Insulation thickness - Thicker insulation for higher voltage systems.
-
Jacket type - PVC or PE sheathing for direct burial, metallic armor for abrasion resistance.
Cable Installation Guidelines
Proper underground cable installation ensures electrical safety and reliability.
Trenching
-
Depth - At least 24 inches for LV cables, 36 inches for HV cables.
-
Width - 10 inches minimum, wider for multiple cables.
-
Excavation - Use manual digging near existing utilities, mechanical trenchers otherwise.
-
Backfilling - Loose soil up to cable height, compacted fill above. Avoid stones or debris.
Cable Handling
-
Inspect cables upon delivery for any damage.
-
Avoid kinks, crush injuries and cuts during handling.
-
Use cable grips for pulling, do not exceed maximum pull force.
Termination
-
Deburr and clean cable ends prior to termination.
-
Use compatible lugs and proper crimping tools.
-
Stagger multicable terminations to reduce congestion.
Protection
-
Provide slack for thermal contraction and expansion.
-
Install warning tape above buried cables.
-
Use conduit for mechanical protection where required.
Testing and Maintenance
Upon installation, cables must be tested before energization.
-
Perform insulation resistance and continuity tests.
-
Check for correct phasing and grounding.
-
Carry out partial discharge tests for high voltage cables.
For maintenance:
-
Inspect cable route periodically for disturbances.
-
Perform insulation tests to detect deterioration over time.
-
Monitor terminations and splices for overheating.
Conclusion
Epoxy resin insulated cables provide superb performance for underground wiring. By selecting appropriate cable sizes, adhering to proper installation practices, and conducting routine maintenance, a safe and reliable underground single phase power system can be implemented. Careful design, planning and skilled execution are key factors for success.